# Parts & Control Panel

### Components

<figure><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FPiih5a1MEkFycjRm8AzX%2FExploded%20Benchy%20Slushy%20Diagram%20.png?alt=media&#x26;token=cf620a77-59b3-4fb0-b130-e432bf2ac078" alt=""><figcaption></figcaption></figure>

### Assembly

{% stepper %}
{% step %}
**Slide the seal to the back of the evapourator and followed by the auger.**

<figure><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FuR7QvvAgSw0vQ2pDX0ek%2FBenchy%20Slushy%20Assembly%201%20(1).png?alt=media&#x26;token=4cf5c56d-982b-462f-b28d-3d7dc04cc265" alt="" width="375"><figcaption></figcaption></figure>
{% endstep %}

{% step %}
**Slide the tank onto the evaporator, then press the pull handle down to lock it into place.**

<figure><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2F2Uss0R9fOeLBPcz7Auc2%2FBenchy%20Slushy%20Assembly%202.png?alt=media&#x26;token=063bd19a-cd68-495a-832b-2f05f82e8561" alt="" width="375"><figcaption></figcaption></figure>
{% endstep %}

{% step %}
**Assemble the spring and spool into the discharge pipe of the tank (spring first), ensure the opening of the spool is facing out.**

<figure><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FRTyIFxn63ygW5jzK3rXF%2FBenchy%20Slushy%20Assembly%203.png?alt=media&#x26;token=2d64e255-9bae-456b-aebf-65d8ddc73045" alt="" width="375"><figcaption></figcaption></figure>
{% endstep %}

{% step %}
**Push the handle into the mounting bracket. Ensure the handle lever is engaged into the top section of the spool. Then fix into place with the handle bolt.**

<figure><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FEcEq2lUYRnRS2K8w4lQX%2FBenchy%20Slushy%20Assembly%204.png?alt=media&#x26;token=e515fcb7-ec59-4165-b505-4dce8a2995d0" alt="" width="375"><figcaption></figcaption></figure>
{% endstep %}

{% step %}
**Add the drip tray cover to the drip tray and push it into position. Place the fill port cover over the fill port.**

<figure><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2Fj5RpM9ZFkHxxcQOg4uo1%2FBenchy%20Slushy%20Assembly%205.png?alt=media&#x26;token=5ecbcbee-ba15-4035-a2f3-daa15d7a5ca6" alt="" width="375"><figcaption></figcaption></figure>
{% endstep %}

{% step %}
**The Benchy Slushy is now fully assembled.**

<figure><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FgHTbYFwRoPxnWdm4HAkH%2FBenchy%20Slushy%20Assembly%206.png?alt=media&#x26;token=b139dccc-210c-4b9f-a1ab-cd4d994d488d" alt="" width="375"><figcaption></figcaption></figure>
{% endstep %}
{% endstepper %}

### Using the Control Panel

<figure><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FuYzZb3LEy4OBRzxp5Ets%2FBenchy%20Slushy%20Control%20Panel%20(2).png?alt=media&#x26;token=0066c7b8-31a8-4f28-8044-e11d033f9065" alt=""><figcaption></figcaption></figure>

[<br>](https://docs.kegland.com.au/products/cooling-equipment/icemaster-beverage-chiller-g40.1-glycol-icebank-with-digital-control/initial-startup-and-testing)

<table><thead><tr><th>Button </th><th width="249">Short Press/Tap</th><th>Long Press/Hold for 3 Second</th></tr></thead><tbody><tr><td><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2Fg7YHAcm6QQXoXesPW6mT%2FBenchy%20Slushy%20Control%20Panel%20-%20ONOFF%20(1).png?alt=media&#x26;token=834d72cb-8f87-4354-a5d3-7113dcda6e83" alt=""></td><td><p>Enters manual mode. </p><p>Increases temperature/viscosity.</p></td><td>Turns the machine's power ON or OFF.</td></tr><tr><td><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FN0IQppABpujkfJm5mcpk%2FBenchy%20Slushy%20Control%20Panel%20-%20Rinse%20(1).png?alt=media&#x26;token=8f7a36ba-4c85-4955-9d55-ebcf4f588f94" alt=""></td><td><p>Enters manual mode.</p><p>Decreases temperature/viscosity.</p></td><td>Starts the automatic rinse cycle.</td></tr><tr><td><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2Fd856KTBBwrwLxkPPKrdp%2FBenchy%20Slushy%20Control%20Panel%20-%20Functions.png?alt=media&#x26;token=64e7caf1-5c7d-45c0-9dd3-d61bf4e7b267" alt=""></td><td>Sets temperature to preset value for each functions.</td><td>Overides the preset temperature with temperature set via manual mode.</td></tr></tbody></table>

| Button                                                                                                                                                                                                                                                                   | Operation                                                           | Function                            |
| ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ------------------------------------------------------------------- | ----------------------------------- |
| ![](https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FhcZAEW3Bpu85nmfJvpMg%2FBenchy%20Slushy%20Control%20Panel%20-%20Temp%20Units%20\(1\).png?alt=media\&token=90efedc3-8433-4091-86c2-50dc87f0d613) | Hold Simulataniously                                                | Changes Temperature Uunits (°C/°F)  |
| ![](https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FHnV6pqRpgwGvjhB6kWQ5%2FBenchy%20Slushy%20Control%20Panel%20-%20Reset.png?alt=media\&token=3a6ba714-81be-48d9-a5ac-b8cc155b754b)                | Turn off machine. Hold simultaniously until you hear a single beep. | Resets to factory default settings. |
|                                                                                                                                                                                                                                                                          |                                                                     |                                     |

| Display                                                                                                                                                                                                                                                           | Meaning                                                                                                                                                                                            |
| ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| ![](https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FYVi0fP6mh1Lxk7UrB1hi%2FBenchy%20Slushy%20Control%20Panel%20-%20Off%20Display.png?alt=media\&token=8ad34a7e-5e27-4f92-b62f-f2dfd9c9a3c5) | Unit has power, is not turned on                                                                                                                                                                   |
| ![](https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2Fk8rkuHweCpCuiqd07Wgg%2FBenchy%20Slushy%20Control%20Panel%20-%20C%20Display.png?alt=media\&token=5f8ff16d-06aa-4920-9dae-008d27b811f3)   | Unit is turned on. Select function.                                                                                                                                                                |
| ![](https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FCbNd4g9x9gNCNtwow5P0%2FBenchy%20Slushy%20Control%20Panel%20-%20EE%20Display.png?alt=media\&token=1cd7392d-8524-4f8f-80d5-110016b7992d)  | EE: Sugar content in mix is too low. Add more sugar or Slushy Booster and wait 10 minutes for mache to resume normal operation.                                                                    |
| ![](https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2F1EnwHwkyCQ0IvQEWmLid%2FBenchy%20Slushy%20Control%20Panel%20-%20E1.png?alt=media\&token=fdd2fb81-a968-4b0a-b68b-e1c81443ca31)            | E1: Heat dissipation fan not rotating; check if the plug is loose; fan damaged. Reset the unit.                                                                                                    |
| ![](https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FLVbjuJlHKc0NSClTzkaE%2FBenchy%20Slushy%20Control%20Panel%20-%20E2.png?alt=media\&token=95bfe1d2-284d-42d9-a98c-9ce0d4092332)            | E2: Front-end temperature sensor failure of the evaporation barrel; check if the plug is loose; sensor damaged. Reset the unit.                                                                    |
| ![](https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FBauoW5tWmgQzvY5DWthM%2FBenchy%20Slushy%20Control%20Panel%20-%20E3.png?alt=media\&token=ff22d0e3-b677-4fa3-af84-b57e4fcda89c)            | <p></p><p>E3: Stirring motor stalled. Check for obstructions in the tank or if hard ice has formed. If so turn up the set point and wait for the liquid to defrost. Reset the unit.</p><p><br></p> |