General Troubleshooting

KL15769 Cannular Compact Semi-Auto Canning Machine | Troubleshooting

Problem
Possible Cause
Solution

Cannular cuts out in use

Power Supply tripping - bearings

Check that the rollers and table bearings spin freely. Too much restriction can cause the power supply to trip

Power Supply tripping - table hieght

Check the table hieght. If the can is pushed against the chuck too hard this can overload the power supply in use.

Faulty Power Supply

Test DC output with multimeter. Replace Power Supply if faulty

Cannular does not stop after complete operation

Faulty Relay or Microswitch

If the Cannular continues running after the both operations are complete it could either be a faulty relay or a faulty micro switch. There is no real way of checking which it might be other than replacing parts.

The relay is located at the back of the unit under the cover near the anderson plug and to access the micro switch you will need to take the blue cog wheel out. The black lobe activates the micro switch after each rotation.

Cannular does not return to correct start position

Microswitch requires adjustment

Can buckles when operation begins

Table height to high