LogoLogo
  • Product Documentation
  • Kegging Equipment
    • Series X User Guide
      • Quick Start Guide
      • Preparation & Setup
        • Keg Types
          • Guide to Commercial Kegs & Couplers
          • Guide to Homebrew/Cornelius Kegs & Disconnects
      • Font Kit Assembly
        • Single, Double and Triple Font Kits
        • Quad Font Kits
        • Tee Bar Font Kits
      • Leak & Pressure Testing
      • Balancing Lines & CO2 Pressure
      • Installation Diagrams
      • Operation
      • Troubleshooting
    • Series X Plus User Guide
      • Quick Start Guide
      • Preparation & Setup
        • Keg Types
          • Guide to Commercial Kegs & Couplers
          • Guide to Homebrew/Cornelius Kegs & Disconnects
      • Font Kit Assembly
        • Single, Double and Triple Font Kits
        • Quad Font Kits
        • Tee Bar Font Kits
        • Super Slim Font Kits
        • Modular Fonts
      • Leak & Pressure Testing
      • Balancing Lines & CO2 Pressure
      • Installation Diagrams
      • Operation
      • Troubleshooting
    • Series 4 User Guide
      • Quick Start Guide
      • Preparation & Setup
        • Keg Types
          • Guide to Commercial Kegs & Couplers
          • Guide to Homebrew/Cornelius Kegs & Disconnects
      • Font Kit Assembly
        • Single, Double and Triple Font Kits
      • Leak & Pressure Testing
      • Balancing Lines & CO2 Pressure
      • Installation Diagrams
      • Operation
      • Troubleshooting
    • KegLand Undercover / Build In / Semi-Integrated Kegerator | Quick Start Guide
      • Preparation & Installation
      • Setup
        • Keg Types
          • Guide to Commercial Kegs & Couplers
          • Guide to Homebrew/Cornelius Kegs & Disconnects
      • Font Kit Assembly
        • Single, Double and Triple Font Kits
        • Quad Font Kits
        • Tee Bar Font Kits
      • Leak & Pressure Testing
      • Balancing Lines & CO2 Pressure
      • Installation Diagrams
      • Operation
      • Troubleshooting
    • Grand Deluxe 3 | Quick Start Guide
      • Specifications
      • Setup & Assembly
      • Installation Diagrams
      • Operation
      • Troubleshooting
  • Brewing Equipment
  • Fermentation Equipment
  • Distilling Equipment
  • benchy range
    • Benchy Sparkling Zero User Manual
      • Technical Specifications
      • Warnings and Installation Checklist
      • Connections & Plumbing
      • Benchy Sparkling Initial Startup Procedure
      • Troubleshooting
      • Warranty (Australia)
  • Pizza | BBQ | Smokers
    • HIZO NEO E13 Pizza Oven User Manual
      • Safety Instructions
      • Parts & Accessories
      • Quick Start Guide
      • Cooking Functions
      • Settings Guide
      • Troubleshooting
      • Error Codes
      • Cleaning & Maintenance
  • Cleaning & Packaging
Powered by GitBook
On this page
  • Video Guide
  • Setup & Assembly
  • Preparation
  • Install Castors
  • Plumb Drip Tray(s)
  • Installing MK4 Regulator onto CO2 Cylinder
  • Attach EVABarrier to the regulator
  • Assembling Font Kits
Export as PDF
  1. Kegging Equipment
  2. Grand Deluxe 3 | Quick Start Guide

Setup & Assembly

Grand Deluxe 3 | Setup & Assembly

PreviousSpecificationsNextInstallation Diagrams

Last updated 1 month ago

Video Guide

Please refer to this video for a detailed walkthrough on assembling a kegerator. This is specific to the Series X range, but most of the information is relevant to all kegerator setups

Setup & Assembly

Before plugging in the unit, ensure it has been standing upright for at least 24 hours after movement

Tools Required: Philips head screwdriver and wrench or spanner

Preparation

  • Cut the straps securing the carton. WIth the assistance of another person, carefully lift the carton off the Grand Deluxe

  • Remove the protective foam and plastic cover

  • Remove any protective plastic from the kegerator before first use

  • Using a Philips head screwdriver, carefully unscrew the brackets that secure the Grand Deluxe to the shipping pallet

Install Castors

Using the supplied bolts, carefully install the castors in each corner and the middle of the Grand Deluxe. If tiliting the unit to install the castor wheels, ensure that the unit is left upright for 24 hours before turning on.

Plumb Drip Tray(s)

The contersunk drip trays are plumbed inside and outside the Grand Deluxe. The drain tube can be emptied into a bucket or similar and simply emptied periodically, or (using the external barb) this can be drained directly to a suitable floor drain.

Installing MK4 Regulator onto CO2 Cylinder

  • Ensure the CO2 cylinder is off by turning the cylinder valve handle clockwise

  • Ensure the regulator dial is completely unscrewed and ensure there is a nylon regulator washer between the type 30 nut and stem and the CO2 cylinder

  • Hand tighten the nut and stem onto the CO2 cylinder then tighten further with a 7 in 1 faucet tap wrench/spanner

Attach EVABarrier to the regulator

  • Make sure the end of the EVABarrier hose doesn’t have any burrs and is cut straight and cleanly. Push the EVABarrier hose line firmly into the duotight fitting on the regulator and ensure it is secure up to the line indicated on the 8mm x FFL duotight fitting

  • On the right hand side of the Grand Deluxe is a gas port. This will need to be drilled out (we recommend an 8mm bit for a good fit) to accomodate the gas line.

  • The gas tubing can then be fed through the gas port into the kegerator. The gas line will also need to be tee'd off if you have two or more taps (duotight tee pieces included with Font Kit)

Assembling Font Kits

Single, Double and Triple Tap Fonts

  1. Remove the cap from the top of the font and ensure the font collar is present at the base of the font prior to attaching any duotight compatible short shanks

  2. Feed the length of beer line through the tap hole on the front of the font and feed the beer line through the slimline nut and convex collet on the inside of the font

  3. Push a 6.5mm x 8mm reducer onto the back of the duotight compatible short shank

  4. Feed the tail and thread of the duotight compatible short shank through the tap hole and align the curvature of the shank and the concave collet with the curvature of the font

  5. Push each length of beer line into a 6.5mm x 8mm reducer which is attached to a short shank

  6. Tighten the slimline nut onto the thread of the duotight compatible short shank to secure the shank to the font tower

  7. Repeat for all other duotight compatible short shanks and beer lines

  8. Feed the beer lines from the duotight compatible short shanks into the kegerator

  9. Attach the font to the top of the kegerator by screwing the font onto the font mounting points using four metric M5 stainless steel screws.

  10. Attach each EVABarrier beer line to a liquid ball lock disconnect or keg coupler

  11. Hand-tighten the tap (sold separately) onto the duotight compatible short shank

  12. Tighten the short shank collar onto the tap using a 7 in 1 tap wrench/spanner

Quadruple Tap Font

  1. First, attach the font to the top of the kegerator using four metric M5 stainless steel screws. The mounting points can be found on the inside of the font and can be attached using a long screwdriver or flexible drill bit

  2. Then attach the duotight compatible short shanks, duotight 6.5mm x 8mm reducer and beer line to the font tower as described in step 11. It is easiest to attach the shanks to the font tower in the order shown

  3. Feed the beer lines from the duotight compatible short shanks into the kegerator.

  4. Attach each EVABarrier beer line to a ball lock disconnect or keg coupler

  5. Hand-tighten the tap (sold separately) onto the duotight compatible short shank

  6. Tighten the short shank collar onto the tap using a 7 in 1 tap wrench/spanner

The Mk4 regulator comes as standard with an 8mm x FFL duotight Fitting ()

TIghtening Short Shank

KL06880