# Single, Double and Triple Font Kits

1. Double check that the the 5mm x 8mm EVABarrier gas line is securely connected to the [MK4 ](https://docs.kegland.com.au/products/series-x-or-user-guide/preparation-and-setup#kl07429-mk4-regulator-1)or [MK5](https://docs.kegland.com.au/products/series-x-or-user-guide/preparation-and-setup#kl30670-mk5-regulator) regulator
2. Feed this through the gas inlet into the kegerator.&#x20;
3. Cut an approximately 1m length of 5mm x 8mm EVABarrier gas line from the end
4. Cut this section into approx 2 x 50cm lengths
5. Push each length into the 8mm duotight Equal Tee Piece
6. Connect the other end of the EVABarrier to the duotight fitting on the coupler or a Ball Lock Disconnect. The fitting will depend on the kegerator setup - whether it is for [commercial (brewery made)](https://docs.kegland.com.au/products/kegging-equipment/kegland-undercover-build-in-semi-integrated-kegerator-or-user-guide/setup/keg-types/guide-to-commercial-kegs-and-couplers) beer or for [homebrew](https://docs.kegland.com.au/products/kegging-equipment/kegland-undercover-build-in-semi-integrated-kegerator-or-user-guide/setup/keg-types/guide-to-homebrew-cornelius-kegs-and-disconnects)
7. Insert the remaining length of 5mm x 8mm EVABarrier (that is connected to the regulator) into the the Equal Tee

<figure><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FaMaZNkWlK6j1pPKsK48n%2FGas%20Lines%20-%20tee%20piece%201.png?alt=media&#x26;token=eccd142c-8bf1-4e3c-8c18-8a3c3eb529cb" alt=""><figcaption><p>Double Gas Line Configuration</p></figcaption></figure>

#### Triple Font

1. Double check that the the 5mm x 8mm EVABarrier gas line is securely connected to the [MK4 ](https://docs.kegland.com.au/products/series-x-or-user-guide/preparation-and-setup#kl07429-mk4-regulator-1)or [MK5](https://docs.kegland.com.au/products/series-x-or-user-guide/preparation-and-setup#kl30670-mk5-regulator) regulator
2. Feed this through the gas inlet into the kegerator.&#x20;
3. Cut an approximately 1.5m length of 5mm x 8mm EVABarrier gas line from the end
4. Cut this section into approx 3 x 50cm lengths
5. Push each length into the 8mm duotight Equal Tee Piece

   <figure><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2F6bPvGSHHH9TPXK0dQ4Ie%2FGas%20Lines%20-%20tee%20piece%202.png?alt=media&#x26;token=84cf6277-6aaf-4f1f-8c25-52e1587e48ca" alt=""><figcaption><p>Triple Gas Line Configuration</p></figcaption></figure>
6. Connect the other end of the EVABarrier to the duotight fitting on the coupler or a Ball Lock Disconnect. The fitting will depend on the kegerator setup - whether it is for [commercial (brewery made)](https://docs.kegland.com.au/products/kegging-equipment/kegland-undercover-build-in-semi-integrated-kegerator-or-user-guide/setup/keg-types/guide-to-commercial-kegs-and-couplers) beer or for [homebrew](https://docs.kegland.com.au/products/kegging-equipment/kegland-undercover-build-in-semi-integrated-kegerator-or-user-guide/setup/keg-types/guide-to-homebrew-cornelius-kegs-and-disconnects)
7. Insert the remaining length of 5mm x 8mm EVABarrier (that is connected to the regulator) into the the Equal Tee

#### Quad Font

1. Double check that the the 5mm x 8mm EVABarrier gas line is securely connected to the [MK4 ](https://docs.kegland.com.au/products/series-x-or-user-guide/preparation-and-setup#kl07429-mk4-regulator-1)or [MK5](https://docs.kegland.com.au/products/series-x-or-user-guide/preparation-and-setup#kl30670-mk5-regulator) regulator
2. Feed this through the gas inlet into the kegerator.&#x20;
3. Cut an approximately 2m length of 5mm x 8mm EVABarrier gas line from the end
4. Cut this section into approx 4 x 50cm lengths
5. Push each length into the 8mm duotight Equal Tee Piece

   <figure><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2F4ASkxlyMRd9ICisox1Hh%2FGas%20Lines%20-%20tee%20piece%203.png?alt=media&#x26;token=fd2954e3-0bd6-40e7-92a5-7bcfa78fbd2c" alt=""><figcaption><p>Quadruple Gas Line Configuration</p></figcaption></figure>
6. Connect the other end of the EVABarrier to the duotight fitting on the coupler or a Ball Lock Disconnect. The fitting will depend on the kegerator setup - whether it is for [commercial (brewery made)](https://docs.kegland.com.au/products/kegging-equipment/kegland-undercover-build-in-semi-integrated-kegerator-or-user-guide/setup/keg-types/guide-to-commercial-kegs-and-couplers) beer or for [homebrew](https://docs.kegland.com.au/products/kegging-equipment/kegland-undercover-build-in-semi-integrated-kegerator-or-user-guide/setup/keg-types/guide-to-homebrew-cornelius-kegs-and-disconnects)
7. Insert the remaining length of 5mm x 8mm EVABarrier (that is connected to the regulator) into the the Equal Tee
