# Operation

### Display Panel Legend

<figure><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FX0vw6j7OaFELFfKtYqhL%2FDisplay%20Panel%20Legend%20(Numbered).png?alt=media&#x26;token=5da4cd5e-11aa-42c0-a741-49e85818edad" alt=""><figcaption><p>Display Panel Legend</p></figcaption></figure>

1. Cooler (Down) Button
2. Warmer (Up) Button
3. Temperature
4. Celsius/Fahrenheit Indicator
5. Fan Indicator
6. Celsius/Fahrenheit Button
7. Fan Button

### Adjusting the Set Point Temperature

To adjust the Set Point Temperature:

1. **Press and hold the Up** <img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FssDP7ElJ3PF4BIhC2DVR%2Fimage.png?alt=media&#x26;token=f3626ebc-b685-4d66-b0d7-420fd46fb5eb" alt="" data-size="line"> **button for 5 seconds.** The display will flash and show the current Set Point Temperature. This is a Child Safety Lock feature to prevent accidentally changing the Set Point Temperature.
2. Press the **Up** <img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FssDP7ElJ3PF4BIhC2DVR%2Fimage.png?alt=media&#x26;token=f3626ebc-b685-4d66-b0d7-420fd46fb5eb" alt="" data-size="line">or **Down** <img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2Fikt8bjgSL6ozMB8hGLIh%2Fimage.png?alt=media&#x26;token=291caf25-c80c-4060-9fae-8589bd83f68d" alt="" data-size="line"> buttons to modify and save the Set Point Temperature. When the display stops flashing the new Set Point Temperature will be saved.

NOTE: The **Up** <img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FssDP7ElJ3PF4BIhC2DVR%2Fimage.png?alt=media&#x26;token=f3626ebc-b685-4d66-b0d7-420fd46fb5eb" alt="" data-size="line">or **Down** <img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2Fikt8bjgSL6ozMB8hGLIh%2Fimage.png?alt=media&#x26;token=291caf25-c80c-4060-9fae-8589bd83f68d" alt="" data-size="line"> buttons must be pressed repeatedly to change the temperature. The temperature will not continue to change if the button is held down - this is a child lock feature.

### Change Display between Celsius and Fahrenheit

To change the displayed temperature between Celsius and Fahrenheit press the **°F/°C button**. Press it again to revert to the previous units.

### Fan Operation

The fan is designed for continuous operation. This will help maintain a consistent temperature. In addition, directing the font fan conduit inside the font can assist with keeping the taps and beer lines cold, which helps to minimise 'first beer foam' issues. If desired the fan can be turned on and off manually using the <img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FN5EKTqNnOIIq0yu2jpA7%2Fimage.png?alt=media&#x26;token=f8182d8c-8e3a-4e64-a778-d3422a7d83ee" alt="" data-size="line">**Fan Button.** When the fan is on, the fan icon will be displayed.

### Temperature Calibration

If there is a large variance between the *displayed* temperature (IE the temperature of the internal temperature probe and the *actual* internal temperature of the kegerator (as measured by a calibrated thermometer) then the Temperature Offset can be adjusted from -10°C to 10°C

A Temperature Offset will *offset* the displayed temperature by the entered amount.

Thus, if the displayed temperature is 2°C but the actual internal temperature is 4°C, an offset of +2°C is required.

Note: In most cases this is not necessary to be adjusted. There will be minor temperature differences in the kegerator due to airflow etc.

#### To Adjust the Offset

1. Press and hold the **Up** <img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FssDP7ElJ3PF4BIhC2DVR%2Fimage.png?alt=media&#x26;token=f3626ebc-b685-4d66-b0d7-420fd46fb5eb" alt="" data-size="line">*and* **Down** <img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2Fikt8bjgSL6ozMB8hGLIh%2Fimage.png?alt=media&#x26;token=291caf25-c80c-4060-9fae-8589bd83f68d" alt="" data-size="line"> buttons for approx 5 seconds - until the display flashes <kbd>**SC**</kbd>
2. Once the display flashes <kbd>**SC**</kbd>, release the **Up** <img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FssDP7ElJ3PF4BIhC2DVR%2Fimage.png?alt=media&#x26;token=f3626ebc-b685-4d66-b0d7-420fd46fb5eb" alt="" data-size="line">or **Down** <img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2Fikt8bjgSL6ozMB8hGLIh%2Fimage.png?alt=media&#x26;token=291caf25-c80c-4060-9fae-8589bd83f68d" alt="" data-size="line"> buttons and press the **°F/°C button. This will display the current Offset Temperature** (which should be 0°)
3. Press the **Up** <img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FssDP7ElJ3PF4BIhC2DVR%2Fimage.png?alt=media&#x26;token=f3626ebc-b685-4d66-b0d7-420fd46fb5eb" alt="" data-size="line">or **Down** <img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2Fikt8bjgSL6ozMB8hGLIh%2Fimage.png?alt=media&#x26;token=291caf25-c80c-4060-9fae-8589bd83f68d" alt="" data-size="line">buttons to modify the Temperature Offset (from 10°C to -10°C)
4. Once the desired value is displayed it will be saved after the display stops flashing (approx. 5 seconds)
5. The display will revert to the current kegerator temperature. This will be different to the value displayed before the offset adjustment was made if the operation was performed correctly.

### Cleaning Kegerator

The exterior of the kegerator can be cleaned with a damp microfibre cloth and a mild spray cleaner. Stainless polish may be used on stainless surfaces (such as fonts etc). [StellarClean PBW](https://kegland.com.au/products/stellarclean-pbw-powerful-brewing-wash-brewery-cleaner-beer-line-cleaner-keg-wash-1kg-35oz) or [StellarOxy](https://kegland.com.au/products/stellaroxy-100-sodium-percarbonate-1kg-35oz) solutions may also be used instead.

Monitor the evaporator plate (at the back of the kegerator on top of the compressor). In normal use this should not be filled with water as the heat generated by the compressor will evaporate normal levels of water. If there is excessive water in the evaporator plate or it is overflowing please refer to [Troubleshooting](https://docs.kegland.com.au/products/kegging-equipment/series-x-plus-or-user-guide/troubleshooting)

The interior of the kegerator may be cleaned in the same manner. It is not uncommon for some mould to be present inside the kegerator due to the nature of use. If present, clean with a mild mould remover spray and a damp microfibre cloth. Be careful to not get mould spray on any fittings such as keg posts or disconnects.