Cooler (Down) Button
Warmer (Up) Button
Temperature
Celsius/Fahrenheit Indicator
Fan Indicator
Celsius/Fahrenheit Button
Fan Button
To adjust the Set Point Temperature:
To change the displayed temperature between Celsius and Fahrenheit press the °F/°C button. Press it again to revert to the previous units.
If there is a large variance between the displayed temperature (IE the temperature of the internal temperature probe and the actual internal temperature of the kegerator (as measured by a calibrated thermometer) then the Temperature Offset can be adjusted from -10°C to 10°C
A Temperature Offset will offset the displayed temperature by the entered amount.
Thus, if the displayed temperature is 2°C but the actual internal temperature is 4°C, an offset of +2°C is required.
Note: In most cases this is not necessary to be adjusted. There will be minor temperature differences in the kegerator due to airflow etc.
Once the desired value is displayed it will be saved after the display stops flashing (approx. 5 seconds)
The display will revert to the current kegerator temperature. This will be different to the value displayed before the offset adjustment was made if the operation was performed correctly.
The exterior of the kegerator can be cleaned with a damp microfibre cloth and a mild spray cleaner. Stainless polish may be used on stainless surfaces (such as fonts etc). StellarClean PBW or StellarOxy solutions may also be used instead.
Monitor the evaporator plate (at the back of the kegerator on top of the compressor). In normal use this should not be filled with water as the heat generated by the compressor will evaporate normal levels of water. If there is excessive water in the evaporator plate or it is overflowing please refer to Troubleshooting
The interior of the kegerator may be cleaned in the same manner. It is not uncommon for some mould to be present inside the kegerator due to the nature of use. If present, clean with a mild mould remover spray and a damp microfibre cloth. Be careful to not get mould spray on any fittings such as keg posts or disconnects.
Press and hold the Up button for 5 seconds. The display will flash and show the current Set Point Temperature. This is a Child Safety Lock feature to prevent accidentally changing the Set Point Temperature.
Press the Up or Down buttons to modify and save the Set Point Temperature. When the display stops flashing the new Set Point Temperature will be saved.
NOTE: The Up or Down buttons must be pressed repeatedly to change the temperature. The temperature will not continue to change if the button is held down - this is a child lock feature.
The fan is designed for continuous operation. This will help maintain a consistent temperature. In addition, directing the font fan conduit inside the font can assist with keeping the taps and beer lines cold, which helps to minimise 'first beer foam' issues. If desired the fan can be turned on and off manually using the Fan Button. When the fan is on, the fan icon will be displayed.
Press and hold the Up or Down buttons for approx 5 seconds - until the display flashes SC
Once the display flashes SC, release the Up or Down buttons and press the °F/°C button. This will display the current Offset Temperature (which should be 0°)
Press the Up or Down buttons to modify the Temperature Offset (from 10°C to -10°C)