Leak & Pressure Testing
KL30670 | KL07429 | KL10870 | KL07443 | KL07436 | Leak & Pressure Testing
Pressure Decay Test
If there is a leak in the system or you suspect that the regulator is leaking, the best way to confirm this is a Pressure Decay Test.
If there are any leaks this can result in the CO2 cylinder becoming empty in a short period.
Initial pressure testing can be performed in two different ways. If leaks are detected an Isolation Test can help determine the location of the leak.
Method 1 - Pressure Decay Test
Connect System
Connect the regulator a CO2 cylinder that definitely has pressure - this can be confirmed by weight.
Isolate the regulator
(MK5 Regulator) Shut the ball valve to prevent gas escaping from the regulator
(MK4 Regulator) Insert a short length of 8mm EVABarrier terminated with a duotight Disconnect, or plug the KL06880 FFL fitting with an 8mm duotight plug.
Check Pressure
Wait for at least two hours then check the pressure reading on the right hand (low-pressure) gauge of the regulator.
If the pressure reading has not changed (so is still reading ~50psi) then there are no leaks in the system.
If the pressure has dropped a noticeable amount then it is very likely there is a leak in the system.
If leaks are detected then proceed to a Detergent Bubble Test to locate the leask
Method 2 - Detergent Bubble Test
Connect System
Connect the regulator a CO2 cylinder that definitely has pressure - this can be confirmed by weight.
Isolate the regulator
(MK5 Regulator) Shut the ball valve to prevent gas escaping from the regulator
(MK4 Regulator) Insert a short length of 8mm EVABarrier terminated with a duotight Disconnect, or plug the KL06880 FFL fitting with an 8mm duotight plug.
Check For Leaks
Using a soapy water solution (washing up liquid and water is perfect for this) in a spry bottle or simply dabbed on, check for leaks at all connections. The soapy water spray will slowly bubble if there are any leaks.
Check the joins for the high and the low-pressure gauages, the join for the outlet and inlet of the regulator and (MK4 only) the FFL duotight fitting as these can be cracked if over-tightened.
IMPORTANT: Do not spray any duotight fittings with StellarSan or phosphoric acid solution to perform a leak test.
Isolation Test
If there is a leak in the system, but the regulator is not leaking as determined by a Pressure Decay Test. If any CO2 leaks are detected, if can be helpful to perform an Isolation Test to determine where the leak is in the system - typically a kegging system (kegerator or glycol system)
Isolate System
Once the system is pressurised, isolate each part of the system.
Turn valve of CO2 cylinder fully off.
Fully unwind the (anti clockwise) the regulator knob
Remove Gas Disconnect from the keg
(If using) Remove Gas Disconnect from gas inlet of kegerator
(If possible) Weigh the CO2 cylinder
Wait at least 12 hours
Test System
After at least 12 hours, if there is a leak in the system we can determine roughly where the leak is after isolating
If the weight of the CO2 cylinder has gone down noticeably, the cylinder possibly has a leak
If the pressure on the regulator has gone down, the regulator, gas line or fittings may have a leak
Test the keg(s) by pulling the PRV. If no CO2 is released then the keg may have a leak.
Once the general location of the leak has been determined by isolation testing, perform a Detergent Bubble Test in order to locate the leak precisely.
NOTE: It is safe to submerge duotight fittings and EVABarrier in water when locating leaks. Regulators cannot be safely immersed
Last updated
