KL52979 Cannular Auto-Lifter 600 | Components & Operation
Start - This begins the seaming process and returns the display to Home Screen when in Settings Mode
Cycle - Press once to highlight the current option. Press again to cycle between rows, allowing different options to be selected.
Enter - This changes the options on the selected line. If a parameter can be changed, this will increase the parameter (Up button)
STOP - Dedicated STOP function. This will override all other operations. If a parameter can be changed, this will decrease the parameter (Down button)
Use the Cycle to highlight the current option. Use the Cycle to cycle between the current highlighted option. To change the displayed, highlighted parameter, use the Enter (Up) button.
Single/Continuous - Toggles between Single or Continuous Operation. In single operation, the Start button will perform one operation. In Continuous operation, the unit will continue to operate continuously with a user set delay between cycles.
Delay - the Delay function affects Continuous Operation only. Use the Cycle button to highlight the Delay (it will flash when selected). Use the Enter (Up) button to increase the delay. Use the STOP (down) button to to decrease the delay. The Delay can be set between 0:00 and 1.59 (M:SS)
Counter - This displays the current number of operations. To reset, highlight using the Cycle button, then use the Enter button to reset to zero.
To enter the Advanced Settings menu, press and hold Cycle for five seconds. This will display the Advanced Settings menu. To exit this menu, hold the Cycle button for five seconds.
In the Advanced Settings screen use the Cycle to highlight the current option. Use the Cycle to cycle between the current highlighted option. To change the displayed, highlighted parameter, use the Enter (Up) button.
This is the amount of pressure the auto table lifter exerts during seaming operation. The higher the number, the higher the force. Typically, PET cans need the least force, aluminium cans require moderate force, and steel (tin) cans require the most force.
Top Force is measured in seconds (range 0.1-0.5 seconds). This determines how long the table pressure is exerted before stopping, hence the larger the time the higher the force. it is important to set this correctly for each type of can.
If seam measurements are correct but a hermetic seal is not achieved a Top Force adjustment may be required.
330ml Aluminum Can 0.02 - 0.1 500ml Aluminium Can 0.02 - 0.06 Sleek PET 330ml Can 0.02 - 0.08 Sleek 250ml Aluminium Can 0.02 - 0.1 Steel (Tin) Can 0.02 - 0.2
The desired language can be selected. The choices are:
[English][Chinese][German][French][Spanish][Swedish][Norwegian][Portuguese][Thai][Hindi][Vietnamese]
Use the Cycle to cycle between the current highlighted option until Language is flashing.. To change the displayed language use the Enter button until the desired language is displayed.
ODO - This is the 'odometer'. This records the total number of times the machine has been through a complete cycle. This is stored in permanent memory and cannot be changed.
The table can be manually operated in Setup Mode - this is helpful when cleaning the unit.
To perform a seaming operation manually use the Start button. Releasing the button immediately stops the seaming operation.
To move the table up manually, use the Enter (Up) button
To move the table down manually, use the STOP (Down) button

























KL52979 Cannular Auto-Lifter 600 | Calibration
All Cannular Auto-Lifter 600 units are factory calibrated prior to shipping. In most cases, the only user adjustment required to achieve a hermetic seal will be the Top Force setting (which is dependant on a number of factors including can size and material). If the chuck is changed by the operator (to accomodate VISY ends, for example) then the unit will require calibration to the new chuck before use. Sometimes calibration settings can drift during operation or transit
Ensure the correct chuck for your can ends is installed and tightened - if seaming B64 cans such as all aluminium cans supplied by KegLand then this will already be installed. Unplug the machine before adjusting rollers. The top cover can remain on but removing it may aid access. It is recommended to remove the cover when calibrating. The cover is held in place with 4mm Allen Bolts.
Remember: to check calibration of a Cannular to achieve a hermetic double seam, use calipers to measure the following after the 1st operation (overlap) and both operations (seam width and length):
Actual overlap (>0.4mm)
2nd Op seam thickness (1.2-1.3mm)
2nd Op seam length (2.3-2.4mm)
For more information and troubleshooting please refer to
The Cannular Auto Lifter automatically raises a lowers the table during the seaming process.
The force applied to the table (that presses the can and end against the chuck) is controlled by the Top Force setting.
The Top Force setting will generally need to be adjusted for different sizes and types of can to be seamed. For example, PET (plastic) cans will generally need less Top Force than aluminium cans.
To adjust the Top Force setting, enter the Advanced Settings menu. Press and hold Cycle for five seconds. This will display the Advanced Settings menu. To exit this menu, hold the Cycle button for five seconds.
In the Advanced Settings screen use the Cycle to highlight the current option. Use the Cycle to cycle between the current highlighted option to select Top Force. To change the displayed Top Force setting, use the Enter (Up) button to increase the setting, or the the STOP (Down) button to decrease the setting.
Top Force is measured in seconds (range 0.1-0.5 seconds). This determines how long the table pressure is exerted before stopping, hence the larger the time the higher the force. it is important to set this correctly for each type of can.
If seam measurements are correct but a hermetic seal is not achieved a Top Force adjustment may be required.
330ml Aluminum Can 0.02 - 0.1 500ml Aluminium Can 0.02 - 0.06 Sleek PET 330ml Can 0.02 - 0.08 Sleek 250ml Aluminium Can 0.02 - 0.1 Steel (Tin) Can 0.02 - 0.2
The Cannular Auto-Lifter 600 can be quickly and easily adjusted to accommodate cans of different diameters.
Place the can on the table and use the lever action to move the table claws to hold the can securely. Once adjusted, you can remove the can and use a 4mm Allen Key to tighten the locking bolt. This will lock the table claws in place so that it is quick and easy to remove and place cans without needing to adjust the table each time. This is strongly recommended if A: you are likely to be seaming cans of the same diameter consistently or B: you will be operating the Cannular Auto-Lifter 600 in Auto mode.
To lock the table claws, use a45mm Allen Key to tighten the central nut as shown. Do not over tighten.
Cans of different heights may need a Top Force adjustment.
The Cannular Auto-Lifter 600 is pre-calibrated and tested in the factory. Generally, adjusting the Top Force to suit cans of different heights and material is all that is required to achieve a hermetic double seam. However, calibration may be required after prolonged use, if changing the chuck (from B64 to VISY, for example) or if the rollers have become slightly off spec for some other reason (this can occur during shipping).
The rollers must be calibrated to the chuck in order to achieve a seam. For a good, hermetic double seam the tolerances are quite tight.
To check calibration it is best to as it can be quite difficult to measure gaps accurately using KL13420
Thus, calibration is performed using feeler gauges to set the gaps between the rollers and the chuck. Seam measurements are used to determine that these have been set correctly.
The below calibration procedure applies to both B64 and VISY chucks. Note that correct calibration is determined by .
To access the Roller & Chuck Assembly, the Drip Tray and Splash Guard must first be removed. These are magnetic and will simply pull off the housing. The Drip Tray must be removed before the Splash Guard.
There are two rollers. The 1st Operation Roller creates the overlap. The 2nd Operation roller completes the same. These are two distinct operations.1st Operation Roller
1sy Operation Roller
2nd Operation Roller
To calibrate any can seamer, the 1st and 2nd operation rollers must be adjusted to the correct seaming position relative to the chuck, in both the X and the Y axis (for each roller)
Before calibrating the rollers, they must be moved so they are in the closest position to the chuck. This is the position that the seaming operation will commence at. The roller assembly is quite easy to move by hand to do this.
Unplug the power from the machine
Manually rotate the roller assembly until the desired operation roller is at its closest position to the chuck. To verify that this is at the closest position, check that the top roller is nudging the guide (as pictured). (It can be helpful to use a phone camera to see this easily)
When calibrating the rollers, always adjust the Y (vertical) axis first.
First, adjust the roller to be calibrated so it is in .
The rollers are on a detente shaft. The lowest vertical position is determined by a round retaining nut. This is held securely in position with a 3mm Allen Key grub screw (B). The retaining nut is marked in mm which can be useful when calibrating the x-axis.
There is another grub screw with a 6mm Allen Key head (closest to the roller on the roller arm) (A). This needs to be loosened to allow roller adjustment in both the x and y axes.
To adjust the roller in the y-axis, loosen the roller arm grub screw slightly. This allows the shaft of the roller to move up and down. NOTE: rotating the retaining nut will also move the x-axis of the roller.
To raise the roller in the y-axis, loosen the arm roller grub screw and raise the roller the desired amount. When in position (checked with feeler gauges) tighten the arm roller grub screw. Once this is tightened, loosen the retaining nut with grub screw A.
The retaining nut can then be lowered to set the position of the roller in the y axis.
To lower the roller in the y-axis, loosen the arm roller grub screw. Next, carefully loosen the retaining nut grub screw. NOTE: It is imperative that the weight of the roller is supported when both nuts are loose to prevent the roller dropping out of the assembly. Carefully lower the roller on the shaft to the desired position (measure with feeler gauges). Once in position tighten the retaining nut grub screw and then the roller arm grub screw to fix the position.
The required Gap Alignment for the 1st Operation Roller:
Gap Y for 1st op: 0.05 mm ± 0.05 mm (as close as possible without touching)
The required Gap Alignment for the 2nd Operation Roller:
Gap Y for 2nd op: 1.2mm
Once the Y-Axis is set, adjust the X-Axis.
To do this, loosen the arm roller grub screw (A) with a 6mm Allen Key. The x-axes is adjusted by carefully rotating the roller shaft. Use the retaining nut grub screw )B) to do this - use this as a lever to rotate the roller on its shaft.
The roller shaft is detented, so rotating the shaft will move the roller closer or further from the chuck along the X-Axis.
Once the X-Axis has been adjusted, carefully tighten the roller arm grub screw with a 4mm Allen Key.
The required Gap Alignment for the 1st Operation Roller:
Gap X for 1st op: 0.4 mm ± 0.1 mm
The required Gap Alignment for the 2nd Operation Roller:
Gap X for 2nd op: 0.2 mm ± 0.1 mm
After positioning the rollers, assess the actual overlap, seam width and seam height using the Guide to confirm seam quality and that parameters are within allowable ranges.
KL52979 Cannular Auto-Lifter 600 | Calibration Overview
In a large commercial operation there are several critical parameters commonly checked in commercial settings include 2nd operation seam thickness, seam gap, actual overlap, body hook butting and tightness.
However, when calibrating a Cannular, very close to the same can seaming confidence can be achieved by checking three easy to measure parameters:
Actual overlap
2nd Op seam thickness
2nd Op seam length
Actual Overlap (1st operation) and 2nd Operation seam thickness are the most important parameters
To achieve a good seam, the Cannular Auto-Lifter must have the following steps correctly calibrated.
Top Force Adjustment. This determines that the can end is snug enough against the chuck for the rollers to operate within very right parameters.
1st operation: This is the most important operation. The 1st Operation Roller takes the end curl and the can flange and begins the forming process. This causes the can end to curl under the can flange, creating an overlap. This overlap is vital to the seaming process. The 1st Operation Roller specification governs the amount of overlap.
2nd operation: compresses and finishes the seam formed by the 1st operation. The 2nd Operation Roller governs the size and fit of the seam after the overlap is created by the 1st operation.
Both rollers must be correctly positioned; incorrect 2nd op positioning can still cause leaks even if 1st op is correct.
When calibrating any canning machine including Cannulars, feeler gauges may be used to check the gaps in the x and y axis between the 1st and 2nd operation rollers. However, the gaps can be quite difficult to measure accurately. However, using calipers it is quite simple to measure the seam after the first and the second operations.
In the above illustration, we can see how the 1st Operation Roller forms the overlap. The 2nd Operation Roller then compresses the seam.
The below images provide a pictorial overview of each operation. This can be helpful when troubleshooting to determine what adjustments need to be made to the roller(s)
1st Operation - forming the overlap
2nd Operation - closing the seam
This determines whether there is sufficient overlap between body hook and cover hook.
Follow these practical steps:
Seam one can using only the 1st operation (Can A)
Seam a second can using both 1st and 2nd operations (Can B).
Remember: to check calibration of a Cannular to acheive a hermetic double seam, use calipers to measure the following:
Actual overlap (>0.4mm)
2nd Op seam thickness (1.2-1.3mm)
2nd Op seam length (2.3-2.4mm)
These three measurements are the best way to determine if the Cannular is correctly calibrated.
KL52979 Cannular Auto-Lifter 600 | Seaming Operation
The Cannular Auto-Lifter has two Seaming Modes - Single and Continuous
To select the desired seaming mode, use the Cycle to highlight the current option - navigate to Single and Continuous. Use the Cycle to cycle between the current highlighted option. To change the displayed, highlighted parameter, use the Enter (Up) button.
Single/Continuous - Toggles between Single or Continuous Operation.
In Single operation, the Start button will perform one operation.
In Continuous operation, the unit will continue to operate continuously with a user set delay between cycles.
Delay - the Delay function affects Continuous Operation only. Use the Cycle button to highlight the Delay (it will flash when selected). Use the Enter (Up) button to increase the delay. Use the STOP (Down) button to decrease the delay.
All Cannular Auto-Lifter 600 units are factory calibrated prior to shipping. In most cases, the only user adjustment required to achieve a hermetic seal will be the (which is dependant on a number of factors including can size and material). If the chuck is changed by the operator (to accomodate VISY ends, for example) then the unit will require calibration to the new chuck before use. Sometimes calibration settings can drift during operation or transit.
Before first use, perform a test run with the selected can to ensure that the Cannular Auto-Lifter 600 is calibrated and the Top Force is correct. If a seal is not achieved, and check again. If this is not successful then may be required.
Place the can to be seamed on the table and adjust if needed using the lever arm to move the table claws. Move the lever clockwise to tighten, anti clockwise to loosen. The can should be held securely in place.
To lock the table claws, use a 4mm Allen Key to tighten the central nut as shown. Do not over tighten.
Fill the can with the beverage to be canned. Best practice for carbonated beverages is to fill and 'cap on foam'. That is, fill the can to close to the top with some foam or head above the top rim of the can.
Place the can end on the foam. Place the can on the table.
Press Start - this begins the seaming process. The table will raise the can to the chuck, the rollers will engage the can and chuck to seam the can. When complete, thew table will lower automatically.
The process for Continuous Can Seaming is exactly the same as Single Can Seaming. However, once the Start button is pressed, the seaming operation will continue until the STOP button is pushed.
The table will raise and lower automatically. The time between can seaming operations is adjustable and can be set by the user using the Delay function.
Delay - the Delay function affects Continuous Operation only. Use the Cycle button to highlight the Delay (it will flash when selected). Use the Enter (Up) button to increase the delay. Use the STOP (down) button to decrease the delay.
The Delay can be set between 0:00 and 1.59 (M:SS)
Continuous Can Seaming operation is ideal for canning runs when multiple cans of the same size need to be filled and seamed. it is not recommended if cans of different sizes or materials are used in one run as different cans often reqyuire a Top Force adjustment to achieve a good seam.
The operation is completely automatic once the filled can and end are placed on the table, and the ntable claws adjusted to hold the can in position. Simply press the Start button to raise the can, seam the can and lower the can, ready for the next can.































Cut away a wedge from the top of the can using an angle grinder (1 mm cutting disk recommended) or a hacksaw if unavailable
Examine final overlap after both operations. This is harder to see; gently pry the seam open slightly with a sharp object to visualize start and finish of the hooks (without significant dimensional change)
Minimum requirement: at least 0.4 mm; over 1 mm is ideal
If first operation overlap is good but final overlap is poor, the 2nd operation roller position may be incorrect — re-evaluate both rollers
Using Can B, take the average of four measurements around the circumference with calipers. The average should be between 1.2–1.3 mm
If smaller: insufficient actual overlap or 2nd op roller too close to the chuck — re-examine overlap and 2nd op gaps
If larger: 2nd op roller may be incorrectly positioned (too far or too close to the chuck), and springback can increase seam thickness
Using calipers measure seam length on Can B. Ideal: about 2.3–2.4 mm
A tight seal can still be achieved with seam length up to 3.3 mm if actual overlap remains sufficient
Short seam length indicates 1st op roller too close to the chuck or 2nd op roller too far in the y-direction
Very long seam indicates 2nd op roller too close to the chuck in the y-direction; this can cause overlap separation and leaks












KL52979 Cannular Auto-Lifter 600 | Seam Troubleshooting
Most of the time, if there are seaming issues with cans after the seaming operation, the issue is incorrect calibration.
Seaming issues encompass any leaks from the seam of the can or end. Inconsisstent seaming also indicates that the calibration of the rollers to the chuck is not 100% accurate.
Canning is a very precise operation, and care must be taken to ensure that all parts (table, chuck and rollers) are calibrated correctly. Failure to calibrate to sepcification will result in inconsistent seams and leak issues.
Some common seaming issues are listed below. it is not possible to cover all possible seaming issues.
It is also helpful to be familiar with the components of the seam before troubleshooting
First, follow this guide to help determine the seaming issue by seaming and cutting two cans.
This will help narrow the seaming issue down.
Seaming issues tend to fall into three broad categories - overlap issues, seam size issues, and other issues.
If the overlap is insufficient as determined after following , try to see where exactly the issue - short or long body hook, short or long cover hook etc as this can help isolate the issue and make correction easier. However, in practice it can be quite difficult to accurately asses the exact cause of overlap issues visually without specialised tools.
Getting an overlap of at least 0.4mm is critical to obtaining a hermetic double seam. Other seam issues are generally less critical and easier to correct once the overlap is correct. The overlap is almost entirely determined by correct 1st Operation calibration.
If the finished seam has good overlap but is too long or too short then this will likely casue leaking issues. Provided there is good overlap (>0.4mm) after both first and second operations then the likely problem is the 2nd Operation Roller is out of spec.
In addition, if the overlap is good after the 1st Operation, but too small after the 2nd Operation, this is likely a 2nd Operation calibration issue
To check the specs of the 2nd operation please follow
To adjust the 2nd Operation Roller relative to the chuck refer to
Always ensure that there is sufficient overlap (>0.4mm) after the 1st Operation before proceeding with further troubleshooting of seam issues. Insufficient overlap is the most common cause of seaming issues. A hermetic double seam cannot be achieved without sufficient overlap. Once there is good overlap after the 1st operation, refer below for further troubleshooting diagnostics.
These three measurements are the best way to determine if the Cannular is correctly calibrated.
Short Overlap - cannot determine exact issue (cover hook, body hook, etc)
If the overlap is less than 0.4mm first check table hieght - ensure the can is snug against the chuck with no possibility of buckling. Next, - this is the most likely reason for a short overlap
Short Cover Hook causing insufficient overlap
1st Operation Roller out of spec - check y-axis Table height out of spec - ensure can is snug against chuck
Long Body Hook causing insufficient overlap
2ns Operation Roller too close in x-axis resulting in over tight seam Table height out of spec - Possibly the can is too snug against the chuck
Finished seam too narrow (>1.3mm)
2nd Operation Roller too close to chuck in x-axis
Adjust 2nd Operation Roller away from the chuck in the x-axis (0.3 mm ± 0.1 mm)
Finished seam too wide (<1.2mm)
2nd Operation Roller too far from chuck in x-axis
Adjust 2nd Operation Roller closer to the chuck in the x-axis (0.3 mm ± 0.1 mm)
Finished seam too tall (>2.4mm)
2nd Operation Roller too close to chuck in y-axis
Adjust 2nd Operation Roller further from the chuck in the y-axis (1.35 mm ± 0.05 mm)
Irregular, V shaped ripples in the finished seam
1: Table height out of spec - ensure can is snug against chuck 2: Rollers or chuck may be damaged - inspect and replace if required 3: 1st Operation Roller out of spec - check overlap after 1st Op only
Body flange protrudes past seam in localised area of seam
Can or end may have been damaged before seaming operation - test with a new can and end One or both Operation Rollers out of spec - check measurements against
False Seam - no overlap at all
This will normally be detected when testing after 1st Operation only. If the body hook is under the cover hook with no overlap it is a false seam. 1: Table height out of spec - ensure can is snug against chuck 2: 1st operation roller y-axis too high or x-axis too far from chuck, or both


Short Body Hook causing insufficient overlap
1st Operation Roller out of spec - check y-axis Table height out of spec - ensure can is snug against chuck
Finished seam too short (<2.3mm)
2nd Operation Roller too far from chuck in x-axis
Adjust 2nd Operation Roller closer to the chuck in the y-axis (1.35 mm ± 0.05 mm)
Overlap too small after 2nd Operation (if overlap >0.4mm after 1st Operation)
2nd Operation Roller too close to chuck in y-axis
Adjust 2nd Operation Roller further from the chuck in the y-axis (1.35 mm ± 0.05 mm)
Horizontal crease in circumference of seam
2nd Operation Roller too close to chuck in x-axis
Adjust 2nd Operation Roller away from the chuck in the x-axis (0.3 mm ± 0.1 mm)
Horizontal crease in circumference of seam
2nd Operation Roller too far from chuck in x-axis
Adjust 2nd Operation Roller closer to the chuck in the y-axis (1.35 mm ± 0.05 mm)
Overlap is shorter after 2nd Operation
If the overlap is good (>0.4mm) after the 1st Operation, but becomes shorter after the 2nd Operation, this is a Sprung Seam. 1. The 2nd Operation is too tight - check x-axis against 2. The 2nd Operation Roller is too low- check y-axis against
Dimples in bottom edge of seam
Rollers or chuck may be damaged - inspect and replace if required Can or end may have been damaged before seaming operation - test with a new can and end Check and adjust - Possibly the can is too snug against the chuck. Do not seam empty cans
Sharp Seam
1st Operation Roller too close to chuck in x-axis 2nd Operation Roller too close to chuck in x-axis
Overlap in spec (>0.4mm) but inconsistent or no hermetic seam
2nd Operation Roller out of spec
and adjust 2nd Operation accordingly
Overlap in spec but inconsistent or no pressure seam
Table Height not correct
Check and adjust
Some cans leak after a run
Calibration not in spec
Check specs against . Adjust accordingly
Some cans leak after a run
Top Force not correct
Check and adjust
Cannular in spec (according to ) but seaming is inconsistent
Rollers or chuck damaged
Inspect rollers and chuck for damage. Replace if damaged










KL52979 Cannular Auto-Lifter 600 | User Guide
The Cannular Auto-Lifter 600 is the ultimate can seaming machine, perfect for homebrewers, cafés, bars, and hospitality venues that need to package drinks quickly and efficiently.
Designed with the most advanced cleaning system on the market, this can seamer guarantees fast, hygienic, and reliable canning with every use.
Versatile Can Seaming: Seam both PET and aluminium cans ranging from 210mL to 700mL with ease. The built-in auto-detecting program adjusts seamlessly—just press the big green button to seal a can in under 5 seconds.
Continuous Mode for Batch Runs: Optimize your workflow with continuous mode. The table platform activates at preset intervals, perfectly syncing your fill and seam times for maximum productivity.
Integrated Power Supply: The latest Cannular model features a fully built-in power supply; no external adapters needed, making setup straightforward and clutter-free.
Exclusive Magnetic Drip Guard & Backsplash Tray: The Cannular Auto-Lifter 600 is the only can seamer in the world with a removable magnetic drip guard and backsplash tray, making cleanup effortless.
Easy Cleaning: The table seat assembly is easily removed with a standard wingnut bolt, ensuring quick and thorough cleaning after use.
Improved Calibration: Fine tune your Cannular with the 1st and 2nd op roller measurement scale bar laser cut directly on the roller apparatus.
1 x Cannular Auto-Lifter 600 Canning Machine (B64 202 Calibrated) 1 x 1000mm IEC Power Cord 1 x Magnetic Removable Clear Splash Guard 1 x Magnetic Removable Stainless Steel Splash Drip Tray 1 x Wingnut Removable Base Adaptor

KL52979 Cannular Auto-Lifter 600 | Cleaning
The exterior of the Cannular Auto-Lifter 600 can be cleaned with a soft microfibre cloth and a mild detergent solution.
It is important to ensure that the roller and chuck assembly is dry after use.
The Splash Guard and the rear drip tray are magnetically mounted and are easily removed for cleaning.
NOTE: The rear drip tray must be removed before the Splash Guard
Removing rear drip tray
Removing Splash Guard
The table can also be easily removed for cleaning.
First, manually raise the table so the underneath can be easily accessed.
Use to do this. Do not attempt to move table by force.
Once the table is raised sufficiently to access the underneath, locate and unscrew the wignut that holds the table asembly in place.
Once the wingnut has been removed, the table assembly can be lifted out in an updwards direction so it can be easily emptied and cleaned.