All pages
Powered by GitBook
1 of 1

Loading...

Components & Operation

KL52979 Cannular Auto-Lifter 600 | Components & Operation

Cannular Auto-Lifter Components

Control Panel

Standard Operation

Start - This begins the seaming process and returns the display to Home Screen when in Settings Mode

Cycle - Press once to highlight the current option. Press again to cycle between rows, allowing different options to be selected.

Enter - This changes the options on the selected line. If a parameter can be changed, this will increase the parameter (Up button)

STOP - Dedicated STOP function. This will override all other operations. If a parameter can be changed, this will decrease the parameter (Down button)

Standard Operation Settings

Use the Cycle to highlight the current option. Use the Cycle to cycle between the current highlighted option. To change the displayed, highlighted parameter, use the Enter (Up) button.

Single/Continuous - Toggles between Single or Continuous Operation. In single operation, the Start button will perform one operation. In Continuous operation, the unit will continue to operate continuously with a user set delay between cycles.

Delay - the Delay function affects Continuous Operation only. Use the Cycle button to highlight the Delay (it will flash when selected). Use the Enter (Up) button to increase the delay. Use the STOP (down) button to to decrease the delay. The Delay can be set between 0:00 and 1.59 (M:SS)

Counter - This displays the current number of operations. To reset, highlight using the Cycle button, then use the Enter button to reset to zero.

To enter the Advanced Settings menu, press and hold Cycle for five seconds. This will display the Advanced Settings menu. To exit this menu, hold the Cycle button for five seconds.

In the Advanced Settings screen use the Cycle to highlight the current option. Use the Cycle to cycle between the current highlighted option. To change the displayed, highlighted parameter, use the Enter (Up) button.

This is the amount of pressure the auto table lifter exerts during seaming operation. The higher the number, the higher the force. Typically, PET cans need the least force, aluminium cans require moderate force, and steel (tin) cans require the most force.

Top Force is measured in seconds (range 0.1-0.5 seconds). This determines how long the table pressure is exerted before stopping, hence the larger the time the higher the force. it is important to set this correctly for each type of can.

If seam measurements are correct but a hermetic seal is not achieved a Top Force adjustment may be required.

330ml Aluminum Can 0.02 - 0.1 500ml Aluminium Can 0.02 - 0.06 Sleek PET 330ml Can 0.02 - 0.08 Sleek 250ml Aluminium Can 0.02 - 0.1 Steel (Tin) Can 0.02 - 0.2

The desired language can be selected. The choices are:

[English][Chinese][German][French][Spanish][Swedish][Norwegian][Portuguese][Thai][Hindi][Vietnamese]

Use the Cycle to cycle between the current highlighted option until Language is flashing.. To change the displayed language use the Enter button until the desired language is displayed.

ODO - This is the 'odometer'. This records the total number of times the machine has been through a complete cycle. This is stored in permanent memory and cannot be changed.

The table can be manually operated in Setup Mode - this is helpful when cleaning the unit.

To perform a seaming operation manually use the Start button. Releasing the button immediately stops the seaming operation.

To move the table up manually, use the Enter (Up) button

To move the table down manually, use the STOP (Down) button

Advanced Settings

Top Force

Note: Cans of different sizes (and thus different heights) will generally require a Top Force adjustment to ensure a good seam

Suggested Top Force range

Note: These numbers are a guide. When calibrating, it is recommended to start at the lower end and increase Top Force if a good seal is not achieved.

Language

Note: The Odometer reading may not be set to 000000 for a brand new machine. This is normal and indicates that the unit has been calibrated and tested during production

Manual Table Operation