KL52979 Cannular Auto-Lifter 600 | Calibration
All Cannular Auto-Lifter 600 units are factory calibrated prior to shipping. In most cases, the only user adjustment required to achieve a hermetic seal will be the Top Force setting (which is dependant on a number of factors including can size and material). If the chuck is changed by the operator (to accomodate VISY ends, for example) then the unit will require calibration to the new chuck before use. Sometimes calibration settings can drift during operation or transit
Ensure the correct chuck for your can ends is installed and tightened - if seaming B64 cans such as all aluminium cans supplied by KegLand then this will already be installed. Unplug the machine before adjusting rollers. The top cover can remain on but removing it may aid access. It is recommended to remove the cover when calibrating. The cover is held in place with 4mm Allen Bolts.
Remember: to check calibration of a Cannular to achieve a hermetic double seam, use calipers to measure the following after the 1st operation (overlap) and both operations (seam width and length):
Actual overlap (>0.4mm)
2nd Op seam thickness (1.2-1.3mm)
2nd Op seam length (2.3-2.4mm)
For more information and troubleshooting please refer to
The Cannular Auto Lifter automatically raises a lowers the table during the seaming process.
The force applied to the table (that presses the can and end against the chuck) is controlled by the Top Force setting.
The Top Force setting will generally need to be adjusted for different sizes and types of can to be seamed. For example, PET (plastic) cans will generally need less Top Force than aluminium cans.
To adjust the Top Force setting, enter the Advanced Settings menu. Press and hold Cycle for five seconds. This will display the Advanced Settings menu. To exit this menu, hold the Cycle button for five seconds.
In the Advanced Settings screen use the Cycle to highlight the current option. Use the Cycle to cycle between the current highlighted option to select Top Force. To change the displayed Top Force setting, use the Enter (Up) button to increase the setting, or the the STOP (Down) button to decrease the setting.
Top Force is measured in seconds (range 0.1-0.5 seconds). This determines how long the table pressure is exerted before stopping, hence the larger the time the higher the force. it is important to set this correctly for each type of can.
If seam measurements are correct but a hermetic seal is not achieved a Top Force adjustment may be required.
330ml Aluminum Can 0.02 - 0.1 500ml Aluminium Can 0.02 - 0.06 Sleek PET 330ml Can 0.02 - 0.08 Sleek 250ml Aluminium Can 0.02 - 0.1 Steel (Tin) Can 0.02 - 0.2
The Cannular Auto-Lifter 600 can be quickly and easily adjusted to accommodate cans of different diameters.
Place the can on the table and use the lever action to move the table claws to hold the can securely. Once adjusted, you can remove the can and use a 4mm Allen Key to tighten the locking bolt. This will lock the table claws in place so that it is quick and easy to remove and place cans without needing to adjust the table each time. This is strongly recommended if A: you are likely to be seaming cans of the same diameter consistently or B: you will be operating the Cannular Auto-Lifter 600 in Auto mode.
To lock the table claws, use a45mm Allen Key to tighten the central nut as shown. Do not over tighten.
Cans of different heights may need a Top Force adjustment.
The Cannular Auto-Lifter 600 is pre-calibrated and tested in the factory. Generally, adjusting the Top Force to suit cans of different heights and material is all that is required to achieve a hermetic double seam. However, calibration may be required after prolonged use, if changing the chuck (from B64 to VISY, for example) or if the rollers have become slightly off spec for some other reason (this can occur during shipping).
The rollers must be calibrated to the chuck in order to achieve a seam. For a good, hermetic double seam the tolerances are quite tight.
To check calibration it is best to as it can be quite difficult to measure gaps accurately using KL13420
Thus, calibration is performed using feeler gauges to set the gaps between the rollers and the chuck. Seam measurements are used to determine that these have been set correctly.
The below calibration procedure applies to both B64 and VISY chucks. Note that correct calibration is determined by .
To access the Roller & Chuck Assembly, the Drip Tray and Splash Guard must first be removed. These are magnetic and will simply pull off the housing. The Drip Tray must be removed before the Splash Guard.
There are two rollers. The 1st Operation Roller creates the overlap. The 2nd Operation roller completes the same. These are two distinct operations.1st Operation Roller
1sy Operation Roller
2nd Operation Roller
To calibrate any can seamer, the 1st and 2nd operation rollers must be adjusted to the correct seaming position relative to the chuck, in both the X and the Y axis (for each roller)
Before calibrating the rollers, they must be moved so they are in the closest position to the chuck. This is the position that the seaming operation will commence at. The roller assembly is quite easy to move by hand to do this.
Unplug the power from the machine
Manually rotate the roller assembly until the desired operation roller is at its closest position to the chuck. To verify that this is at the closest position, check that the top roller is nudging the guide (as pictured). (It can be helpful to use a phone camera to see this easily)
When calibrating the rollers, always adjust the Y (vertical) axis first.
First, adjust the roller to be calibrated so it is in .
The rollers are on a detente shaft. The lowest vertical position is determined by a round retaining nut. This is held securely in position with a 3mm Allen Key grub screw (B). The retaining nut is marked in mm which can be useful when calibrating the x-axis.
There is another grub screw with a 6mm Allen Key head (closest to the roller on the roller arm) (A). This needs to be loosened to allow roller adjustment in both the x and y axes.
To adjust the roller in the y-axis, loosen the roller arm grub screw slightly. This allows the shaft of the roller to move up and down. NOTE: rotating the retaining nut will also move the x-axis of the roller.
To raise the roller in the y-axis, loosen the arm roller grub screw and raise the roller the desired amount. When in position (checked with feeler gauges) tighten the arm roller grub screw. Once this is tightened, loosen the retaining nut with grub screw A.
The retaining nut can then be lowered to set the position of the roller in the y axis.
To lower the roller in the y-axis, loosen the arm roller grub screw. Next, carefully loosen the retaining nut grub screw. NOTE: It is imperative that the weight of the roller is supported when both nuts are loose to prevent the roller dropping out of the assembly. Carefully lower the roller on the shaft to the desired position (measure with feeler gauges). Once in position tighten the retaining nut grub screw and then the roller arm grub screw to fix the position.
The required Gap Alignment for the 1st Operation Roller:
Gap Y for 1st op: 0.05 mm ± 0.05 mm (as close as possible without touching)
The required Gap Alignment for the 2nd Operation Roller:
Gap Y for 2nd op: 1.2mm
Once the Y-Axis is set, adjust the X-Axis.
To do this, loosen the arm roller grub screw (A) with a 6mm Allen Key. The x-axes is adjusted by carefully rotating the roller shaft. Use the retaining nut grub screw )B) to do this - use this as a lever to rotate the roller on its shaft.
The roller shaft is detented, so rotating the shaft will move the roller closer or further from the chuck along the X-Axis.
Once the X-Axis has been adjusted, carefully tighten the roller arm grub screw with a 4mm Allen Key.
The required Gap Alignment for the 1st Operation Roller:
Gap X for 1st op: 0.4 mm ± 0.1 mm
The required Gap Alignment for the 2nd Operation Roller:
Gap X for 2nd op: 0.2 mm ± 0.1 mm
After positioning the rollers, assess the actual overlap, seam width and seam height using the Guide to confirm seam quality and that parameters are within allowable ranges.