All pages
Powered by GitBook
1 of 1

Loading...

Troubleshooting

KL30670 | KL07429 | KL10870 | KL07443 | KL07436 | Troubleshooting

Problem
Possible Cause
Solution

CO2 Leak at Cylinder Connection

Type 30 Nut not tightened sufficiently

Damaged seal.

Ensure nut-hand-wheel is hand-tight only. Inspect and replace (MK5) Ensure Type 30 Nut is tightened with a wrench or spanner. Inspect and replace (MK4)

KL41546 KL46855 KL21906 KL06798 KL02233 KL02226 KL45612 KL05456 KL30663 KL15646 KL47609

KL03070 KL09164 KL05333

No CO2 Flow

CO2 cylinder valve closed

Open cylinder valve

CO2 cylinder empty

Check weight of cylinder to verify (compare against TARE weight). Replace or refill cylinder if required

Regulator output pressure too low

Increase output pressure (turn adjustment knob clockwise to desired pressure)

Ball valve closed

Open Ball Valve (MK5 only)

Sintered valve blocked

Remove sintered valve from Type 30 Stem. Replace valve if this allows pressure to flow

Pressure Creep (output pressure slowly increases regardless of adjustment knob setting)

Contaminant in regulator; worn seat cap assembly.

Refer

Cannot control pressure - pressure increases no matter the setting

Pressure creep

Refer

PRV Activating Frequently, CO2 leaking from PRV

Output pressure set too high

Reduce output pressure. Turn adjustment knob anti-clockwise to reduce pressure

Possible pressure creep

Refer

CO2 cylinder empty/using CO2 quickly

Possible leak

Refer

Optional Accessories & Spare Parts

Replacement PRVs (Pressure Relief Valves)

Heavy Duty Black Gauge Guard for MK5 Regulator
Replacement Plastic Knob for MK5 Regulator
Replacement Plastic Knob for MK4 Regulator
High Pressure Extension Hose - (180cm)
Regulator Low Pressure Gauge 0-100 psi
Regulator High Pressure Gauge 0-4500 psi
Replacement Red MK5 Easy-Tight Washer
MK4 Nylon Regulator Washer
MK5 - Regulator Replacement Diaphragm & Seat Assembly
MK4 - Replacement Regulator Diaphragm and Seat Assembly
Type 30 CO2 Cylinder 3 Ways Adaptor
Cornelius Type Pressure Relief Valve (PRV) (GREY 100psi / 7BAR)
Cornelius Type Pressure Relief Valve (PRV) (GREEN 65psi / 4.5BAR)
Cornelius Type Pressure Relief Valve (PRV) (RED 35psi / 2.5BAR)
seal if damaged
seal if damaged
Pressure Creep
Pressure Creep
Pressure Creep
Leak & Pressure Testing