KL30670 | KL07429 | KL10870 | KL07443 | KL07436 | Troubleshooting
CO2 Leak at Cylinder Connection
Type 30 Nut not tightened sufficiently
Damaged seal.
Ensure nut-hand-wheel is hand-tight only. Inspect and replace (MK5) Ensure Type 30 Nut is tightened with a wrench or spanner. Inspect and replace (MK4)
KL41546 KL46855 KL21906 KL06798 KL02233 KL02226 KL45612 KL05456 KL30663 KL15646 KL47609
KL03070 KL09164 KL05333
No CO2 Flow
CO2 cylinder valve closed
Open cylinder valve
CO2 cylinder empty
Check weight of cylinder to verify (compare against TARE weight). Replace or refill cylinder if required
Regulator output pressure too low
Increase output pressure (turn adjustment knob clockwise to desired pressure)
Ball valve closed
Open Ball Valve (MK5 only)
Sintered valve blocked
Remove sintered valve from Type 30 Stem. Replace valve if this allows pressure to flow
Pressure Creep (output pressure slowly increases regardless of adjustment knob setting)
Contaminant in regulator; worn seat cap assembly.
Refer
Cannot control pressure - pressure increases no matter the setting
Pressure creep
Refer
PRV Activating Frequently, CO2 leaking from PRV
Output pressure set too high
Reduce output pressure. Turn adjustment knob anti-clockwise to reduce pressure
Possible pressure creep
Refer
CO2 cylinder empty/using CO2 quickly
Possible leak
Refer