STC-1000 Operating Instructions
STC-1000 Operating Instructions
Function
The STC-1000 is a multi purpose Temperature Controller. It allows for temperature controller, adjustable hysteresis, offset calibration and output relay delay. An alarm will sound if the temperature limits are exceeded or a sensor issue is detected
Specification & Size
♦Front panel size: 75x34.5mm LxW ♦Product size: 75x34.5x85mm LxWxD ♦Mounting size: 71x29mm LxW ♦Sensor length: 2m (including the probe)
Technical Parameters
♦Temperature measuring range: -50°C - 99°C
♦Accuracy: ±1°C (-50°C-70°C)
♦Power supply: 220VAC±10%, 50/60Hz
♦Sensor: NTC sensor (1PC)
♦Relay contact capacity: Cool (10A/250VAC); Heat(10A/250VAC)
♦Ambient temperature: 0°C - 60°C
♦Relative humidity: 20-85% (No condensate)
♦Resolution: 0.1°C
♦Sensor Error Delay: 1 minute
♦Power consumption: <3W
♦Storage temperature: -30°C - 75°C
Controls

Cool Indicator
Heat indicator
3 digit LED Display
Power Button - Power On/Off, Confirm Parameter Adjustment
Button - Set
Up Button
Down Button
Indicator Light Status
Cooling Indicator
Flashing
Compressor Delay On
Cooling Indicator
On
Cooling Relay On
Heating Indicator
On
Heating Relay On
Set Indicator
On
Paramater Setting Status On
Key Operation
Set Parameter
Hold the Button for 3 seconds to enter Parameter Modifying Mode. The Set Indicator light will illumintae, and the display will show F 1
Change the displayed Parameter by using the Up Button or the
Down Button.
Press theButton to display the current setting for the displayed parameter
To adjust the value of the parameter, hold theButton and use the
Up Button or the
Down Button to change the value of the parameter. To save the new value, press and release the
Power Button.
If the Power Button is not pushed withn 10 seconds, the modified value will not be saved
If there is an error when setting a different parameter value, the display will show Er and revert to normal status within 3 seconds
Operation
To turn the STC-1000 OFF or ON, press and hold the
Power Button for three seconds
Under normal working conditions, the STC-1000 displays the current measured temperature. The Heat and Cool indicator will illuminate to show if the Heating or Cooling relay is active
Cooling activates when the measured temperature is greater than the Set Point temperature and the Hysteresis. If the Cooling indicator is flashing, this indicates that the Compressor Delay is active. Cooling will begin when this period ends. When the measured temperature reaches the Set Point temperature, the Cooling Relay will deactivate and cooling will stop.
Heating activates when the measured temperature is less than the Set Point temperature and the Hysteresis. When the measured temperature reaches the Set Point temperature, the Heating Relay will deactivate and heating will stop.
Menu | Parameter Settings
F1
Temperature Set Point Value
-50.0 - 99.9°C
10.0°C
F2
Hysteresis Set Value
0.3 - 10.0°C
0.5°C
F3
Compressor Delay Time
1 - 10 minutes
3 minutes
F4
Temperature Calibration (offset) Value
-10.0 - 10.0°C
0°C
Temperature Set Point - this is the set point temperature that you wish to maintain using the STC-1000 Controller
Hysteresis - this is the allowed value above/below the set point before cooling/heating activates
Compressor Delay Time - this si the delay before the Cooling relay activates (to prevent excessive compressor use)
Temperature Calibration (offset) Value - this allows the temperature probe to be calibrated - see Temperature Calibration below
NOTE: If the STC-1000 is pre-installed then the default settings mat differ from the above
Temperature Calibration
If there is a large variance between the displayed temperature (IE the temperature of the temperature probe and the actual internal temperature (as measureed by a calibrated thermometer) then the Temperature Offset can be adjusted from -10°C to 10°C
A Temperature Offset will offset the displayed temperature by the entered amount.
Thus, if the displayed temperature is 2°C but the actual internal temperature is 4°C, and offset of +2°C is required.
Note: In most cases this is not necessary to be adjusted.
Error Codes
EE Error
This indicates the temperature probe is unplugged, damaged or faulty. Press any key to cancel the alarm and investigate the source of the error.
HH Error
This indicates the measured temperature as exceeded the temperature mesuring range (-50°C - 99°C). Heating and Coolling will be suspended. Press any key to cancel the alarm. The system will revert when the measured temperature is back within range.
Safety
Ensure correct wiring is followed (see below for wiring diagram)
Ensure unit is not connected to electricity when wiring unit
Do not use unit in areas that exceed temperature, humidity range of the device
Ensure it is connected to a suitable power outlet
Minimise/avoid contact between the temperature probe and the power lead to avoid interference
Wiring Diagram

Last updated