> For the complete documentation index, see [llms.txt](https://docs.kegland.com.au/products/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.kegland.com.au/products/fittings/duotight-female-flare-fittings.md).

# Duotight Female Flare Fittings

Ensure correct fit for KL06880 duotight FFL fittings

Duotight fittings are an easy way to make leakproof seals quickly and reliably. The female flare&#x20;fittings are a unique fitting that seals without the use of an o‐ring, washer or thread tape.

These flare fittings require a small amount of deformation in the tapered/flared profile so a specific&#x20;amount of compression is achieved.

This instruction sheet will enable you to easily determine the correct level of seal compression&#x20;without the need to tighten the fitting excessively.

<figure><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FmuLf4ixxUKg1myBfAGAx%2FKL06880%20-%20duotight%20%E2%80%93%208mm%20(5-16%E2%80%9D)%20Female%20x%20FFL%20Female%20Thread%20-%2000.jpg?alt=media&amp;token=df0a04c5-9d2b-4c06-9b2c-794cafa956c1" alt=""><figcaption></figcaption></figure>

{% stepper %}
{% step %}

### Hand Tighten The Duotight

By hand, tighten the female flare (FFL) Duotight fitting onto the male flare (MFL) of the ball lock&#x20;disconnect or regulator thread. Do this up as tight as you can with your fingers alone.

<p align="center"><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2F0EJInVwwh8FvhgzcKxBn%2FIMG_3756.JPG?alt=media&amp;token=a1930a6c-237f-4f1b-9f15-3bc410c16b24" alt=""></p>
{% endstep %}

{% step %}

### Mark Both Sides

Use a marker and mark both the FFL and MFL sides of the fitting.

<p align="center"><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FqhYl5IMbQamsbCHIe574%2FIMG_3757.JPG?alt=media&amp;token=6ee1a03f-90a7-4257-8895-1315a48b3c3d" alt=""></p>
{% endstep %}

{% step %}

### Tighten With Shifter

Paying attention to the markings in step 2, tighten the duotight fitting with a shifter and rotate the&#x20;fitting an additional 180 degrees so the two markings are on opposite sides.

<p align="center"><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2FGkRWDNIpTkF8GQ1cgbsG%2FIMG_3758.JPG?alt=media&amp;token=d737912e-8f25-4ba4-833c-7df01f2e56e6" alt=""></p>
{% endstep %}

{% step %}

### Test For Leaks

Submerse the whole disconnect in a glass of water while the fitting is at 30psi and check for&#x20;leaks/bubbles. If any bubbles are detected, repeat step 3 and rotate the fitting by another 90°.

<p align="center"><img src="https://66344119-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FJhj88FK6X4FnrYkWzTvI%2Fuploads%2F7G9QPqHXzJDih6ky76mo%2FIMG_3759.JPG?alt=media&amp;token=b1354e28-f3b7-4839-8383-b764676ce119" alt=""></p>
{% endstep %}