Troubleshooting & Maintenance
Benchy Carbon | Troubleshooting
Troubleshooting
Benchy Carbon not reaching Set Point Temperature
Set Point may be incorrect
Check the Set Point Temperature and adjust if needed.
Insufficient Clearance
A minimum of 100mm clearance is required on each side of the chiller to ensure adequate heat dissipation for the condensers. Move the unit into open space to improve cooling efficiency
Insufficient 'bounce back' time
We recommend that after every 500ml dispensed you should allow approximately 2 minutes to recover.
Dispensing Issues
Beer too foamy/frothy
Insufficient CO2 pressure
The CO2 pressure generally needs to be set higher for a glycol setup to keep CO2 in solution. Refer Dispensing Pressure and adjust
Incorrect Beer Line
KL06231 5mm x 8mm EVABarrier is recommended. Wider or narrower diameter line may cause pouring issues
Pouring too quickly
If the beverage is dispensing too quickly this can cause foaming and also flat beer. Refer Adjusting Line Length for more information
Beer not dispensing
Frozen Lines/Product
If the Benchy Carbon temperature is lower than the freezing point of the beverage then the product lines may freeze. Check the Set Point Temperature and adjust if needed.
Incorrect Check Valve Installation
If using a commercial coupler such as an A Type or D Type Coupler check the installation of the liquid check valve. If this is not corect the liquid flow will be blocked.
Incorrect Flow Control Adjustment
Check that the Flow Control is not set too low as this can prevent liquid from pouring.
No CO2/gas
If there is no headspace pressure in the keg it is not possible to dispense from the keg. Refill or replace the CO2 cylinder with a full one
Cleaning & Maintenance
Only use KegLand approved cleaners such as StellarOxy and StellarClean and sanitisers such as Phosphoric Acid and StellarSan to clean and sanitise your product lines.
An easy way to clean your product lines with a gas source is to use a KL20220 Gas Free Ball Lock Line Cleaning Kit. Simply fill a PET bottle with correctly diluted Stellarclean or Stellaroxy solution. Hook up your liquid ball lock disconnect on your product line to the carbonation cap nad pump the line cleaning kit to push cleaner through the product lines.
The exterior of the Benchy Carbon should be cleaned with a mild detergent and a clean, lint free microfibre cloth.