Troubleshooting
Troubleshooting Benchy Sparkling Issues
Last updated
Troubleshooting Benchy Sparkling Issues
Last updated
No sparkling water from tap
Incorrect pressure setup
The CO2 pressure must be 10-15psi lower than the mains pressure. Adjust the CO2 regulator until the CO2 pressure is lower than the main pressure by 15psi
Low mains pressure
If the CO2 is set to the recommended 55psi but only gas (not water) comes from the sparkling water tap then the mains pressure may be too low. You will need to
Incorrect plumbing
Ensure that the tap is correctly connected to the Sparkling Out push fitting of the Benchy Sparkling
No chilled still water from tap
Incorrect plumbing
Ensure that the tap is correctly connected to the Chilled Out push fitting of the Benchy Sparkling
Water not carbonated/not fizzy enough
Incorrect CO2 pressure
The CO2 pressure is mainly responsible for carbonation levels. The higher the CO2 pressure, the higher the carbonation. 55psi is the recommended level for good carbonation.
Internal reservoir not fully carbonated
Once the Benchy is setup, initial carbonation can take up to 48 hours. After this time continuous carbonation will be effective
Water too fizzy
CO2 pressure too high
Reduce the CO2 pressure (and mains water pressure as needed). 55psi is the recommened pressure for good carbonation levels
Sparkling and/or chilled water not cold
Incorrect setpoint temperature
Not enough time elapsed
There iis an internal 2L reservoir. This will take several hours to cool after the initial setup is complete. Continual cooling and carbonaion will be effective after this time